Alpha pure Banner

GX SERIES USER GUIDE FOR CARTRIDGE STYLE ELEMENT FILTERS

MS Series User Instructions (NOTE: Float Drain MDV-400)

COMPRESSED AIR FILTERS
& ELEMENTS

compressed air filters

MAINTENANCE

  • To get optimum utility there must be a suitable connection that fits to the inlet and outlet piping.
  • Cut the air supply and discharge remaining air.
  • Control the Filter height with respect to the annotations set forward in the catalogue.
  • The Filters must always be mounted in a vertical position.
  • Pay attention to the arrow which shows air flow direction on the label of housing.
  • Check the Filter body making sure that it is correctly fastened.
  • Connect the system to the air supply and check the parts under pressure.

TECHNICAL SPECIFICATIONS

Maximum working Pressure (barg / psi) 20 / 290
Maximum working Temperature (°C /°F) 80 / 176
Minimum working Temperature (C /°F) 2/ 36

Instruction Manual

FIRST INSTALLATION

  • Filter elements must be replaced when the differential pressure indicator level increases. Nevertheless, element should be replaced once a year.
  • Cut the air supply and discharge remaining air.
  • Pull out the body of housing by turning clockwise.
  • Take out the dirty element by turning the handle clockwise
  • Place the new element on to the housing bowl head, Pinecessary/ling provided in the housing
  • Clean and lubricate the threads of body before installation.
  • Connect the system to air supply to check for any leakages.

Turn the bowl of the filter clockwise to take it apart from the head. (Pic.3)

To replace the dirty element, first turn handle clockwise on the element and take out it from the bowl. (Pic.4)

gx series
gx series
Gently tighten the drain relief valve by using a wrench. (Pic.8)
gx series

REPLACING ELEMENT

Cut the air supply (Pic.1) and discharge remaining air by loosening the drain on the bottom of the Filter using a wrench (Pic.2)
gx series

Turn the bowl of the filter clockwise to take it apart from the head. (Pic.3)

To replace the dirty element, first turn handle clockwise on the element and take out it from the bowl. (Pic.4)

gx series
gx series
Take out the dirty element (Pic. 5) Place the new one in to the bowl (Pic.6)
gx series
Assemble the Filter bowl to the Filter head by turning it counterclockwise. (Pic.7)
gx series
Gently tighten the drain relief valve by using a wrench. (Pic.8)
gx series
Connect the system to air supply to check for any leakages. (Pic.9)
Connect the system to air supply to check for any leakages. (Pic.9)